NON-OIL-RESISTANT HARD-SERVICE CORDS #14, 16, 18, SJ

Rating: 60℃ / 75℃ / 90℃ / 105℃, 300V

Standard: UL 62

No. of Conductor Conductor Insulation Jacket
  AWG Size Sectional Area (mm2) Construction (No./mm) Nom. Thick. (mm) Nom. Diam. (mm) Nom. Thick (mm) Nom. Diam. (mm)
2 18 0.824 41/0.160 0.76 2.85 0.76 7.35
2 16 1.310 26/0.253 0.76 3.10 0.76 7.95
2 14 2.080 41/0.253 0.76 3.50 0.76 8.70
2 12 3.310 65/0.253 0.76 4.00 1.14 10.50
3 18 0.824 41/0.160 0.76 2.85 0.76 7.80
3 16 1.310 26/0.253 0.76 3.10 0.76 8.40
3 14 2.08 41/0.253 0.76 3.50 0.76 9.30
3 12 3.310 65/0.253 0.76 4.00 1.14 11.00
4 18 0.824 41/0.160 0.76 2.85 0.76 8.60
4 16 1.310 26/0.253 0.76 3.10 0.76 9.20
4 14 2.080 41/0.253 0.76 3.50 0.76 10.30
4 12 3.310 65/0.253 0.76 4.00 1.14 12.10
5 18 0.824 41/0.160 0.76 2.85 0.76 9.30
5 16 1.310 26/0.253 0.76 3.10 0.76 10.10
5 14 2.080 41/0.253 0.76 3.50 0.76 11.10
5 12 3.310 65/0.253 0.76 4.00 1.14 13.25